Specification |
sFOG-120H |
sFOG-120 |
Note |
Bias Stability (°/h) |
0.005 |
0.01 |
°/h, RMS, 10s smooth room temperature static test |
Bias Stability (°/h) |
0.01 |
0.01 |
°/h, RMS, 100s smooth 1℃/min temperature changing rate, static test |
Bias Repeatability |
0.005 |
0.01 |
°/h |
Scale Factor Non-linearity |
5 |
10 |
ppm |
Scale Factor Asymmetry (ppm) |
2 |
2 |
ppm |
Random Walk |
0.001 |
0.01 |
°/h1./2 |
Dynamic Range |
±1000 |
±1000 |
°/s |
Volume |
Φ120 x 33 |
Φ120 x 31 |
mm |
Weight |
<660 |
<650 |
gram |
Steady State Power Consumption |
<2.5 |
<2.5 |
W |
Communication Port |
RS-422 |
RS-422 |
|
Specification sFOG-98 Note Bias Stability (/h) 0.02 /h, RMS, 10s smooth room temperature static test Bias Stability (/h) ...
Specification sFOG-70H sFOG-70 Note Bias Stability (/h) 0.03 0.1 /h, RMS, 10s smooth room temperature static test Bias St...
Specification sFOG-120H sFOG-120 Note Bias Stability (/h) 0.005 0.01 /h, RMS, 10s smooth room temperature static test Bia...
Thank you for your message and we will contact you within 24 Hours of your submission to resolve your issue